INT149 - Metering Data Daily

Trigger type

Event triggered

Published

Daily Settlements Process

Audience

Market participant and Distributor

Output file name

int149_v[n]_metering_data_daily_[p]~yyyymmddhhmmss.csv

Report purpose

This report provides meter data, by MIRN Metering Identification Reference Number. A unique number that identifies each gas meter., for up to the past 14 days of available data as part of settlement pre-processing. It can be used as an indication of what the prudential processing will use to calculate settlement exposure is likely to be for Market participant. Market participants and distribution business may wish to use this report to review the status of the metering data as the report provides a quality flag that indicates whether the data is estimated or not.

Audience notes

It should be noted that this report is likely to have a significant proportion of the data estimated due to data collection difficulties and should only be used as a guide as to the actual consumption on the day. Accurate meter readings are only available for the final settlement process at month+18 business days.

This report is only for the Declared Transmission Network (DTS Declared Transmission System (Victoria). Victoria’s gas transmission system, operated by AEMO.) Network.

A report is produced 3 business days after the gas date and contains up to the last 14 days of available data as part of settlement pre-processing.

This is a Market participant and distribution business specific report.

Content notes

Each report contains the:

  • meter identifier

  • gas date

  • hourly time interval (where 1= 6:00 AM to 7:00 AM, 2= 7:00 AM to 800 AM, until the 24th interval)

  • injection point or withdrawal point

  • energy and quality description

  • date and time when report was produced

Data content

Name

Data Type

No Nulls

Primary Key

CQ

Comments

mirn

varchar 10

True

True

N

Meter Identifier

gas_date

varchar 20

True

True

N

Gas day being reported e.g. 30 Jun 2007 06:00:00

ti

integer

True

True

N

Time Interval

e.g. 1=6:00 AM, 2= 7 AM etc.

flag

varchar 10

True

False

N

'INJ' (injection point) or (withdrawal point)

energy_gj

Numeric(18,3)

False

False

N

hourly energy (Gj)

uafg_adj_energy_gj

Numeric(18,3)

False

False

N

UAFG adjusted Hourly energy (Gj)

quality_desc

char 1

False

False

N

Gas Meter Data Quality Flags are detailed in Section 6.8

current_date

varchar 20

True

False

N

Time Report Produced (e.g. 30 Jun 2007 06:00:00)