INT149 - Metering Data Daily
Trigger type |
Event triggered |
Published |
Daily Settlements Process |
Audience |
Market participant and Distributor |
Output file name |
int149_v[n]_metering_data_daily_[p]~yyyymmddhhmmss.csv |
Report purpose
This report provides meter data, by MIRN Metering Identification Reference Number. A unique number that identifies each gas meter., for up to the past 14 days of available data as part of settlement pre-processing. It can be used as an indication of what the prudential processing will use to calculate settlement exposure is likely to be for Market participant. Market participants and distribution business may wish to use this report to review the status of the metering data as the report provides a quality flag that indicates whether the data is estimated or not.
Audience notes
It should be noted that this report is likely to have a significant proportion of the data estimated due to data collection difficulties and should only be used as a guide as to the actual consumption on the day. Accurate meter readings are only available for the final settlement process at month+18 business days.
This report is only for the Declared Transmission Network (DTS Declared Transmission System (Victoria). Victoria’s gas transmission system, operated by AEMO.) Network.
A report is produced 3 business days after the gas date and contains up to the last 14 days of available data as part of settlement pre-processing.
This is a Market participant and distribution business specific report.
Content notes
Each report contains the:
-
meter identifier
-
gas date
-
hourly time interval (where 1= 6:00 AM to 7:00 AM, 2= 7:00 AM to 800 AM, until the 24th interval)
-
injection point or withdrawal point
-
energy and quality description
-
date and time when report was produced
Data content
Name |
Data Type |
No Nulls |
Primary Key |
CQ |
Comments |
---|---|---|---|---|---|
mirn |
varchar 10 |
True |
True |
N |
Meter Identifier |
gas_date |
varchar 20 |
True |
True |
N |
Gas day being reported e.g. 30 Jun 2007 06:00:00 |
ti |
integer |
True |
True |
N |
Time Interval e.g. 1=6:00 AM, 2= 7 AM etc. |
flag |
varchar 10 |
True |
False |
N |
'INJ' (injection point) or (withdrawal point) |
energy_gj |
Numeric(18,3) |
False |
False |
N |
hourly energy (Gj) |
uafg_adj_energy_gj |
Numeric(18,3) |
False |
False |
N |
UAFG adjusted Hourly energy (Gj) |
quality_desc |
char 1 |
False |
False |
N |
Gas Meter Data Quality Flags are detailed in Section 6.8 |
current_date |
varchar 20 |
True |
False |
N |
Time Report Produced (e.g. 30 Jun 2007 06:00:00) |