Standing data access rules
The CATS Standing Data Access Rules The rules specifying which CATS Standing Data can be accessed, as specified in section 41.5 of the CATS Procedures. specify which items each Role The role a company has with a connection point in CATS. A single company can have more than one role associated with a NMI. within a Jurisdiction participating jurisdiction (defined in the NER) can access. The items are grouped by the following:
-
Meter Register
-
NMI Data
-
NMI Datastream
-
NMI Participant Relations
-
Register ID
They define:
-
Which Role can initiate a request for NMI Standing Data.
-
Which NMI Standing Data items return for a request.
-
The NMI Data Access Rules may be defined by Jurisdiction.
-
The NMI Standing Data items returned to a FRMP or LNSP in all Jurisdictions on a successful request. For more details, see Standing Data for MSATS.
To fully understand the standing data access rules, you must understand the CATS History Model.
Metering coordinator standing data search
Metering Coordinators (MC Meter Coordinator; The Role Code used in MSATS for an MC is RP.) can access NMI Standing Data See National Electricitiy Rules to identify a LARGE NMI See Relevant Rules or Procedures Classification to arrange a change of MC. For details about the NMI Standing Data items returned to an MC, see MSATS Procedures All of the following procedures: CATS Procedures, WIGS Procedures, MDM Procedures, NMI Standing Data Schedule, NMI Procedure, and Part A of the NEM RoLR Processes.: CATS Customer Administration and Transfer Solution. A set of procedures, principles and obligations made under the National Electricity Rules as part of Market Settlement and Transfer Solutions (MSATS), and applicable to NMI (National Metering Identifier) small and large classifications. Procedure Principles and Obligations.
Participant Access
The participants have access to view the data according to the Standing data access rules.
Data Item |
Description |
Jurisdiction |
Standing Data Access Rights |
NMI Discovery |
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DRSP |
FRMP |
ENLR |
LNSP |
MDP |
MPB |
MPC |
RP |
RoLR |
NEMM |
NSP2 |
Search 1 |
Search 2 |
Search 3 |
MC Search |
|||
Meter Malfunction Exemption Number |
The exemption number granted by AEMO when a meter malfunction exemption is granted |
ALL |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
n/a |
Yes |
Yes |
Yes |
Yes |
n/a |
Yes |
Meter Malfunction Exemption Expiry Date |
The end date of the meter malfunction exemption |
ALL |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
n/a |
Yes |
Yes |
Yes |
Yes |
n/a |
Yes |