Interval Metering Data Results

Interval Metering data results from MTRD or MDMT

Interval Metering data results from MTRD

Interval Metering data result fields explained

Field

Description

A/H

A - indicates this is the current record for this period

H - indicates this is a history record (another more recent record has replaced it)

Interval Time

The 5-minute interval reading

Interval Value

The value of the read in kWh. Depending on the meter register type, this value may be an actual read or the difference between the last meter read time and the previous meter read time

Load Date

The date and time the Metering Data was loaded into MSATS

MDP Version Date

The date and time stamp the MDP’s system assigned to the record. It is the date and time the Metering Data was loaded into the MDP’s system

Settlement Date

The date for the period covered by this read

Status

The status of each reading; the codes and their meanings are:

A: actual

E: estimated

S: substituted data

F: substitutions that are considered final (that is, not to be replaced by actual data)

Substitution Type

The substitution type derived from the NEM12 or NEM13 method flag.

Suffix

The MDM Datastream suffix record, as defined for this NMI in the CATS Standing Data