Interval Metering Data Results
Interval Metering data results from MTRD or MDMT
Interval Metering data results from MTRD
Interval Metering data result fields explained
Field |
Description |
---|---|
A/H |
A - indicates this is the current record for this period H - indicates this is a history record (another more recent record has replaced it) |
Interval Time |
The 5-minute interval reading |
Interval Value |
The value of the read in kWh. Depending on the meter register type, this value may be an actual read or the difference between the last meter read time and the previous meter read time |
Load Date |
The date and time the Metering Data was loaded into MSATS |
MDP Version Date |
The date and time stamp the MDP’s system assigned to the record. It is the date and time the Metering Data was loaded into the MDP’s system |
Settlement Date |
The date for the period covered by this read |
Status |
The status of each reading; the codes and their meanings are: A: actual E: estimated S: substituted data F: substitutions that are considered final (that is, not to be replaced by actual data) |
Substitution Type |
The substitution type derived from the NEM12 or NEM13 method flag. |
Suffix |
The MDM Datastream suffix record, as defined for this NMI in the CATS Standing Data |