Basic types
AveragedDailyLoad
Purpose: The average daily load for a given data steam.
MSATS Market Settlement and Transfer Solutions. The procedures published by AEMO under clause 7.2.8 of the National Electricity Rules, which include those governing the recording of financial responsibility for energy flows at a connection point, the transfer of that responsibility between market participants, and the recording of energy flows at a connection point. Data Model The definition of the interface to participants of data published by AEMO for gas or electricity. A database conforming to the Data Model can contain a local copy of all current participant-specific data recorded in the main database. The Data Model includes database tables, indexes, and primary keys. Column – AverageDailyLoad.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
AveragedDailyLoad |
xsd:integer |
simple |
Electricity_r36 |
DirectionIndicator
You can handle this element using the NetworkTariffCode, if so, remove the corresponding data element.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
DeviceSerialNumber |
maxLength value=”12” xsd:string enumerated list:
|
simple |
Electricity_r36 |
EmbeddedNetworkIdentifier
Purpose: Identify an embedded network.
MSATS Data Model Column – EmbNetIdCode, EmbNetParent, EmbNetChild.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
EmbeddedNetworkIdentifier |
maxLength value=”10” xsd:string ≤ 10 chars |
simple |
Electricity_r41 |
MeterCommunicationsEquipmentType
MSATS Data Model Column – CommEquipType.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterCommunicationsEquipmentType |
maxLength value=”4” xsd:string ≤ 4 chars |
simple |
Electricity_r41 |
MeterCommunicationsProtocol
MSATS Data Model Column – CommProtocol.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterCommunicationsProtocol |
maxLength value=”50” xsd:string ≤ 50 chars |
simple |
Electricity_r41 |
MeterDataValidations
MSATS Data Model Column – DataValidations
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterDataValidations |
maxLength value=”50”xsd:string ≤ 50 chars |
simple |
Electricity_r41 |
MeteringType
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeteringType |
xsd:string maxLength value=”240” |
simple |
Electricity_r41 |
MeterProgram
MSATS Data Model Column – MeterProgram.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterProgram |
maxLength value=”30” xsd:string ≤ 30 chars |
simple |
Electricity_r41 |
MeterTestCalibrationProgram
MSATS Data Model Column – TestCalibProgrm.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterTestCalibrationProgram |
maxLength value=”50” xsd:string ≤ 50 chars |
simple |
Electricity_r41 |
MeterTestPerformedBy
MSATS Data Model Column – TestPerformedBy.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterTestPerformedBy |
maxLength value=”20” xsd:string ≤ 20 chars |
simple |
Electricity_r41 |
MeterTestResultAccuracy
MSATS Data Model Column – TestResultAccuracy.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterTestResultAccuracy |
totalDigits value=”8” fractionDigits value=”5” decimal format 999.99999 |
simple |
Electricity_r41 |
MeterTestResultNotes
MSATS Data Model Column – TestResultNotes.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterTestResultNotes |
maxLength value=”50” xsd:string ≤ 50 chars |
simple |
Electricity_r41 |
MeterTransformerType
MSATS Data Model Column – TransformerType.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterTransformerType |
maxLength value=”20” xsd:string ≤ 20 chars |
simple |
Electricity_r41 |
MeterUserAccessRights
MSATS Data Model Column – UserAccessRights.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterUserAccessRights |
maxLength value=”50” xsd:string ≤ 50 chars |
simple |
Electricity_r41 |
RegisterIndexValue
Purpose – Identify Meter Register The meter register data stored in MSATS, which includes both the metering register and other data. Index Value.
Detail: Maximum of 15 characters per line.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
RegisterIndexValue |
maxLength value=”15” xsd:string ≤ 15 chars |
simple |
Electricity_r41 |