Meter Register types
CustomerFundedMeter
Purpose: Identifies the customer has funded the purchase of the meter, leading to a reduction in the meter charges allocated to the incumbent retailer. Required for the network bill reconciliation. Also has an impact on contracts offered to customers by prospective retailers.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
CustomerFundedMeter |
xsd:Boolean |
simple |
Electricity_r41 |
DisplayType
In WA, readings are collected from some customers by means of self-reader cards that have blank dials printed on them mimicking the layout of the meter display. This attribute defines the type of display on the meter and is used to define what style of self-read card is sent to the End-use Customer when a retailer requests a self-read card arrangement. It also helps define the type of screen to display for internet captured readings.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
DisplayType |
maxLength value=”20” minLength value=”1” whitespace value=”collapse” xsd:string 1–20 chars |
simple |
Electricity_r41 |
KeyCode
Purpose: Identifies the type of key and/or its location to access a meter at a site. Required in standing data as the Franchise Market Retailer See Relevant Rules or Procedures still carries responsibility for performing site activities for some areas of the network.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
KeyCode |
maxLength value=”8” minLength value=”1” whitespace value=”collapse” xsd:string 1–8 chars |
simple |
Electricity_r41 |
MeterAdditionalSiteInformation
MSATS Market Settlement and Transfer Solutions. The procedures published by AEMO under clause 7.2.8 of the National Electricity Rules, which include those governing the recording of financial responsibility for energy flows at a connection point, the transfer of that responsibility between market participants, and the recording of energy flows at a connection point. Data Model The definition of the interface to participants of data published by AEMO for gas or electricity. A database conforming to the Data Model can contain a local copy of all current participant-specific data recorded in the main database. The Data Model includes database tables, indexes, and primary keys. Column – AddlSiteInfo
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterAdditionalSiteInformation |
maxLength value=”100” xsd:string ≤ 100 chars |
simple |
Electricity_r41 |
MeterAssetManagementPlan
MSATS Data Model Column – AssetMgmtPlan
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterAssetManagementPlan |
maxLength value=”50” xsd:string ≤ 50 chars |
simple |
Electricity_r41 |
MeterCalibrationTables
MSATS Data Model Column – CalibrationTables.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterCalibrationTables |
maxLength value=”50” xsd:string ≤ 50 chars |
simple |
Electricity_r41 |
MeterControlledLoad
MSATS Data Model Column – ControlledLoad
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterControlledLoad |
xsd:string length value=”100” |
simple |
Electricity_r41 |
MeterDataConversion
MSATS Data Model Column – DataConv.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterDataConversion |
xsd:string ≤ 100 chars |
simple |
Electricity_r41 |
MeterDemand
MSATS Data Model Column – Demand1, Demand2.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterDemand |
xsd:integer totalDigits value=”8” |
simple |
Electricity_r41 |
MeterEstimationInstructions
MSATS Data Model Column – EstInstruct
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterEstimationInstructions |
xsd:string ≤ 50 chars maxLength value=”50” |
simple |
Electricity_r41 |
MeterHazard
MSATS Data Model Column – MeterHazard.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterHazard |
xsd:string ≤ 12 chars maxLength value=”12” |
simple |
Electricity_r41 |
MeterInstallationTypeCode
MSATS Data Model Column – MeterInstallCode.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterInstallCode |
xsd:string ≤ 8 chars maxLength value=”8” |
simple |
Electricity_r41 |
MeterLocation
MSATS Data Model Column – MeterLocation.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterLocation |
xsd:string ≤ 50 chars maxLength value=”50” |
element |
Electricity_r41 |
MeterManufacturer
MSATS Data Model Column – MeterManufacturer.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterManufacturer |
xsd:string ≤ 15 chars maxLength value=”15” |
simple |
Electricity_r41 |
MeterModel
MSATS Data Model Column – MeterModel.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterModel |
maxLength value=”12” xsd:string ≤ 12 chars |
simple |
Electricity_r41 |
MeterPassword
MSATS Data Model Column – Password.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterPassword |
maxLength value=”20” xsd:string ≤ 20 chars |
simple |
Electricity_r41 |
MeterPoint
MSATS Data Model Column – MeterPoint.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterPoint |
maxLength value=”2” xsd:string ≤ 2 chars |
simple |
Electricity_r41 |
MeterReadTypeCode
MSATS Data Model Column – MeterReadType.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterReadTypeCode |
maxLength value=”4” xsd:string ≤ 4 chars |
simple |
Electricity_r41 |
MeterRegisterIdentifier
Purpose: Identifies a register within a meter.
MSATS Data Model Column – RegisterId.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterRegisterIdentifier |
maxLength value=”10”, xsd:string ≤ 10 chars |
simple |
Electricity_r41 |
MeterRemotePhoneNumber
MSATS Data Model Column – RemotePhoneNumber.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterRemotePhoneNumber |
maxLength value=”12” xsd:string ≤ 12 chars |
simple |
Electricity_r41 |
MeterRoute
MSATS Data Model Column – MeterRoute.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterRoute |
maxLength value=”12” xsd:string ≤ 12 chars |
simple |
Electricity_r41 |
MeterStatusCode
Purpose: Status code of Meter Register The meter register data stored in MSATS, which includes both the metering register and other data. Data.
MSATS Data Model Column – MeterStatus.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterStatusCode |
xsd:string enumerated list:
|
simple |
Electricity_r41 |
MeterTransformerLocation
MSATS Data Model Column – TransformerLocation.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterTransformerLocation |
maxLength value=”30” xsd:string ≤ 30 chars |
simple |
Electricity_r41 |
MeterTransformerRatio
MSATS Data Model Column – TransformerRatio.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
MeterTransformerRatio |
maxLength value=”20 xsd:string ≤ 20 chars |
simple |
Electricity_r41 |
SupplyPhase
Purpose: Defines a list of valid supply phase.
Field |
Restrictions |
aseXML |
Schema |
---|---|---|---|
SupplyPhase |
xsd:string enumerated list (see SupplyPhase list) |
simple |
Electricity_r41 |
1-phase |
2-phase |
3-phase |
Other Multi-phase |