Reason Codes

New reason codes

Reason Code

Reason code Description

Detailed Description

100

Incorrect Meter Multiplier

For use when correcting an originally applied incorrect meter multiplier data

101

Temporarily Connection Point unmetered

Applicable when a Connection Point is temporarily unmetered

102

Customer by-pass

For use when the customer has by-passed the meter

103

Network by-pass

For use whe the Network by-passed the meter to get supply to the customer under the impression of a faulty meter

104

Transposed Channel

For use when meter data streams have been transposed (for example, ToU with controlled load)

105

Transposed Channel – UoM Correction

Applicable when data channels have been transposed (for example, KWH with KVARH)

106

Transposed Channel – Reverse Polarity

For use when meter is inversrely wired from install or where reverse polarity alarm occurs effectively, swapping the registration between export and import registers

107

Transposed Meter

Applicable when correcting the data as a result of crossed meters

108

Network by-pass extreme weather

Applicable when the network by-passed the meter to get supply to the customer because an extreme weather event has affected meter

109

Defined load method

Applicable where Retailer/LNSP provide profile data based on off-market meter or other measured data that best represents the Connection Point load

For more information about reason codes, see Meter Data File Format Specification NEM12 and NEM13.