|
Name |
|
|
Comment |
DISPATCH_UNIT_CONFORMANCE details the conformance of a scheduled units operation with respect to a cleared target on dispatch interval basis. |
|
DISPATCH_UNIT_CONFORMANCE data is confidential. Source DISPATCH_UNIT_CONFORMANCE shows data for every 5 minutes for all scheduled units Volume Rows per day: 288 per scheduled unit |
|
Name |
Comment |
Value |
|
Visibility |
Data in this table is: |
Private |
|
Name |
|
DUID |
|
INTERVAL_DATETIME |
|
Name |
|
LASTCHANGED |
|
Name |
Data Type |
Mandatory |
Comment |
|
INTERVAL_DATETIME |
DATE |
X |
Dispatch Interval that the conformance data applies to |
|
DUID |
VARCHAR2(20) |
X |
Dispatchable Unit Identifier |
|
TOTALCLEARED |
NUMBER(16,6) |
|
Dispatch Target - MW |
|
ACTUALMW |
NUMBER(16,6) |
|
Unit output measured at the conclusion of the dispatch interval - MW (MWB) |
|
ROC |
NUMBER(16,6) |
|
Rate of Change in direction of error MW per hour |
|
AVAILABILITY |
NUMBER(16,6) |
|
Offered unit capacity - MW (MWO) |
|
LOWERREG |
NUMBER(16,6) |
|
Lower Regulation FCAS enabled - MW (FCL) |
|
RAISEREG |
NUMBER(16,6) |
|
Raise Regulation FCAS enabled - MW (FCR) |
|
STRIGLM |
NUMBER(16,6) |
|
Calculated small trigger error limit in MW |
|
LTRIGLM |
NUMBER(16,6) |
|
Calculated large trigger error limit in MW |
|
MWERROR |
NUMBER(16,6) |
|
Calculated actual error |
|
MAX_MWERROR |
NUMBER(16,6) |
|
Max of mwerror while that unit was not in a normal state |
|
LECOUNT |
NUMBER(6) |
|
Large trigger error count. Reset when mwerror changes sign |
|
SECOUNT |
NUMBER(6) |
|
Small trigger error count. Reset when mwerror changes sign |
|
STATUS |
VARCHAR2(20) |
|
Unit conformance status. |
|
PARTICIPANT_STATUS_ACTION |
VARCHAR2(100) |
|
Participant action required in response to current STATUS |
|
OPERATING_MODE |
VARCHAR2(20) |
|
conformance operating mode |
|
LASTCHANGED |
DATE |
|
Last date and time record changed |
|
|
|