Table: DISPATCHLOAD_BNC

DISPATCHLOAD_BNC

Name

DISPATCHLOAD_BNC

Comment

DISPATCHLOAD_BNC was discontinued on 30 September 2009. Prior: DISPATCHLOAD_BNC gives binding intra-regional network constraints (BNC) re-run dispatch results for all scheduled generating units. DISPATCHLOAD_BNC has a similar structure to DISPATCHLOAD but does not repeat input type data (e.g. InitialMW, AGCStatus) since these values are available from DISPATCHLOAD.


Description

DISPATCHLOAD_BNC was discontinued on 30 September 2009.

In accordance with the "Arrangements for Managing Risks Associated with Transmission Network Congestion" set of rule changes the Dispatch Binding Network Constraints re-run was discontinued on September 30, 2009.

Source

The occurrences of Over-constrained dispatch (OCD) or binding intra-regional network constraints (BNC) re-runs are ad hoc, with significant dependencies on the configuration or events in the physical power system. Potentially updated every 5 minutes.

DISPATCHLOAD_BNC shows data produced every 5 minutes for all units when they have over-constrained dispatch, with own data being confidential until the next day.

Volume

Rows per day: ~14000

Mb per month: 25% of DISPATCHLOAD

The basis of estimation on the number of rows is on a 25% occurrence rate for BNC runs

Note

A flag exists for each ancillary service type such that a unit trapped or stranded in one or more service type can be immediately identified. The flag is defined as follows:

Flag Name

Bit

Description

Field value

Enabled

0

The unit is enabled to provide this ancillary service type.

>1

Trapped

1

The unit is enabled to provide this ancillary service type, however the profile for this service type is causing the unit to be trapped in the energy market.

3

Stranded

2

The unit is bid available to provide this ancillary service type, however, the unit is operating in the energy market outside of the profile for this service type and is stranded from providing this service.

4


Notes

Name

Comment

Value

Visibility

Data in this table is:

Private; Public Next-Day


Primary Key Columns

Name

DUID

INTERVENTION

RUNNO

SETTLEMENTDATE


Index Columns

Name

LASTCHANGED


Index Columns

Name

DUID

LASTCHANGED


Content

Name

Data Type

Mandatory

Comment

SETTLEMENTDATE

DATE

X

End date and time of the dispatch interval

RUNNO

NUMBER(3,0)

X

Dispatch run no; always 1

DUID

VARCHAR2(10)

X

Dispatchable unit identifier

INTERVENTION

NUMBER(2,0)

X

Intervention flag if intervention run

CONNECTIONPOINTID

VARCHAR2(12)

 

Connection point identifier for DUID

DISPATCHMODE

NUMBER(2,0)

 

Dispatch mode for fast start plant (0 to 4).

TOTALCLEARED

NUMBER(15,5)

 

Target MW for end of period

RAISEREG

NUMBER(15,5)

 

Raise Regulation reserve target

RAISE5MIN

NUMBER(15,5)

 

Raise 5 min reserve target

RAISE60SEC

NUMBER(15,5)

 

Raise 60 sec reserve target

RAISE6SEC

NUMBER(15,5)

 

Raise 6 sec reserve target

LOWERREG

NUMBER(15,5)

 

Lower Regulation reserve target

LOWER5MIN

NUMBER(15,5)

 

Lower 5 min reserve target

LOWER60SEC

NUMBER(15,5)

 

Lower 60 sec reserve target

LOWER6SEC

NUMBER(15,5)

 

Lower 6 sec reserve target

RAISEREGFLAGS

NUMBER(3,0)

 

Raise Reg status flag

RAISE5MINFLAGS

NUMBER(3,0)

 

Raise 5min status flag

RAISE60SECFLAGS

NUMBER(3,0)

 

Raise 60sec status flag

RAISE6SECFLAGS

NUMBER(3,0)

 

Raise 6sec status flag

LOWERREGFLAGS

NUMBER(3,0)

 

Lower Reg status flag

LOWER5MINFLAGS

NUMBER(3,0)

 

Lower 5min status flag

LOWER60SECFLAGS

NUMBER(3,0)

 

Lower 60sec status flag

LOWER6SECFLAGS

NUMBER(3,0)

 

Lower 6sec status flag

LASTCHANGED

DATE

 

Last date and time record changed